Three-core XLPE Insulation Armoured Power Cable (25/35KV)

In stock

Category:
Detailed Product Description
CONDUCTOR: 99.99% Copper INSULATION: XLPE
BENDING: 12XO.D INSULATION COLOR: Blue, Red,Yellow
OPERATING TEMP: 90 Degree CABLE MARK: Printing Or Embossing
MAIN MARKET: Aisa

26/35KV Three Core Screened High Voltage XLPE Insulated Cable 3x95SQMM

Construction
CU/XLPE/PVC Electrical Cable
– Round bare Copper core stranded according to IEC 60228
– Inner semi-conductive layer
– Core insulation XLPE
– Outer semi-conductive layer
– Semi-conductive tape
– Copper tape screen
– Filler
– PVC inner sheath
– PP Wrapping
– PVC outer sheath (red or black)

Code name:
YJ: XLPE insulation
V: PVC sheath
32: Steel wire armoring—3 cores
22: Steel tape armoring—3 cores
72: Aluminum wire armoring—1 core
62: Stainless steel tape armoring—1 core
ZR: Flame resistant

Application
Used for power transmission and distribution line with voltage rated at 35kV and below.
High and Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals, in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain.

MV(26kv 35kv) Power Cable
Model and Description Uo/U(Um)=3.6/6(7.2), 6/6(7.2), 6/10(12), 8.7/10(12), 8.7/15(17.5), 12/20(24), 18/30(36), 21/35(40.5), 26/35(40.5)kV No.of Core Conductor cross-section area(mm2)
xlpe insulation 1 core 3 core 10 16 25 35 70 95 120 150 185 240 300 400 500 630 sq mm
Cu core
YJV, N2XSY;PVC sheathed power cable
YJV22;steel tape armoured,PVC sheathed power cable
YJV32,YJV42;steel wire armoured ,PVC sheathed power cable
Al Core
YJLV, NA2XSY; PVC sheathed power cable
YJLV22;steel tape armoured,PVC sheathed power cable
YJLV32,YJLV42;steel wire armoured ,PVC sheathed power cable

 

Standard
International: IEC 60502, IEC 60228
China: GB/T 12706
Other standards such as BS, DIN and ICEA upon request

Technical data:
Maximum Conductor Temperature: under normal (90 OC), emergency (130OC) or short circuit no more than 5 s (250℃) conditions.
Min. Ambient Temp. 0 OC, after installation and only when cable is in a fixed position
Min. Bending Radius: 15 x cable O.D for single core
12 x cable O.D for multi core

Test voltage 6 / 10 kV [kV] 21 / 5 min.
12 / 20 kV [kV] 42 / 5 min.
18 / 30 kV [kV] 63 / 5 min.
Temperature range in motion -5°C till +70°C
fixed -20°C till +70°C
Operating temperature short circuit °C 250
Short circuit time max. [sec] 5
Bending radius min. x diameter 15
Flammability standard EN 60332-1-2

 

Three-core XLPE Insulation Armoured Power Cable (25/35KV)
Nominal
Cross
sectional
Area
Nominal
Insulation
Thickness
Approx.
overall
diameter
of cable
Approx.weight of cable kg/km Approx.
overall
diameter
of cable
Approx.weight of cable kg/km Approx.
overall
diameter
of cable
Approx.weight of cable kg/km Approx.
overall
diameter
of cable
Approx.weight of cable kg/km
YJV YJLV YJV22 YJLV22 YJV32 YJLV32 YJV42 YJLV42
MM2 MM MM YJV YJLV MM YJV23 YJLV23 MM YJL33 YJLV33 MM YJV43 YJLV43
3X50 10.5 81 5510 4780 91 10300 9680 92 11780 10860 98 17060 16140
3X70 10.5 86 7830 6520 95 11480 10200 96 13010 11720 59 18260 16940
3X95 10.5 91 8910 7300 99 12750 11010 100 14380 12630 61 19830 18080
3X120 10.5 94 9960 7700 102 13930 11730 103 15600 13400 109 21320 19110
3X150 10.5 98 11230 8410 106 15360 12590 107 16960 14200 112 22940 20180
3X185 10.5 101 12610 9140 110 16930 13500 111 18670 15210 117 24800 21350
3X240 10.5 106 14600 10170 115 19250 14800 116 21010 16530 122 27340 22860
3X300 10.5 111 16940 10320 120 12790 16230 121 23420 17820 129 29950 24350
3X400 10.5 118 20190 11690 125 24530 17065 127 26380 18910 133 23440 25980
3X500 10.5 122 22990 12500 131 27300 17900 134 29630 20300 140 26550 27230