1.Application
1)XLPE insulated copper power cable has a number of advantages compared with paper insulated and PVC insulate cables.
2)XLPE Copper cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level.
3) It can be applied in high temperature of 90 degree for a long time.
4)Flame-retardant and non-flame-retardant XLPE cables can be manufactured by three kinds of technological processes: peroxidation, silanization and irradiation.
5)The flame-retardant cable covers three classes of A, B, C and low-smoke low-halogen, low-smoke non-halogen cables.
2.Standard
Our XLPE Copper cable are produced according to IEC 60502, IEC60332, and IEC 60754, even some of our indexes are superior to the above international IEC standards. Meanwhile, we can produce cables according to other standards and can design the XLPE cables with some certain special properties according to customers’ requirements.
XLPE Copper cable can be applied in high temperature for a long time and has bigger current capacity. In the same environment conditions, compared with paper insulated and PVC insulated cables, XLPE cable can lessen the cross section by 1 or 2 grades.
3.Specification:
1). Rated Voltage, No. of Core and Range of Sectional Area
Rated voltage (kv) Sectional area (mm2) No. of core |
1st class | 0.6/1 | 1.8/3 | 3.6/6 | 6/10 | 8.7/15 | 12/20 | 18/30 | 21/35 |
2nd class | 1/1 | 3/3 | 6/6 | 8.7/10 | 12/15 | 18/20 | – | 26/35 | |
1 Core | 1.5-800 | 25-800 | 25-1200 | 25-1200 | 35-1200 | 50-1200 | 50-1200 | 50-1200 | |
2 Core | 1.5-185 | 25-185 | |||||||
3 Core | 1.5-400 | 25-400 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 | |
4 Core | 2.5-400 | 25-400 | |||||||
5 Core | 2.5-400 | 25-400 |
Nominal cross sectional Area |
Nominal Insulation Thickness |
Approx. overall diameter of cable |
Approx.weight of cable kg/km |
Approx. overall diameter of cable |
Approx.weight of cable kg/km |
Approx. overall diameter of cable |
Approx.weight of cable kg/km |
Approx. overall diameter of cable |
Approx.weight of cable kg/km |
||||
YJV | YJLV | YJV22 | YJLV22 | YJV32 | YJLV32 | YJV42 | YJLV42 | ||||||
MM2 | MM | MM | YJV | YJLV | MM | YJV23 | YJLV23 | MM | YJV33 | YJLV33 | MM | YJV43 | YJLV43 |
25 | 4 . 5 | 46 | 2380 | 1910 | 50 | 3406 | 2929 | 52 | 4745 | 4262 | 55 | 6203 | 5719 |
35 | 4 . 5 | 49 | 2818 | 2132 | 53 | 3896 | 3210 | 54 | 5381 | 4589 | 59 | 6824 | 6132 |
50 | 4 . 5 | 52 | 3299 | 2405 | 56 | 4441 | 3547 | 59 | 5935 | 5030 | 61 | 8195 | 7291 |
17 | 4 . 5 | 56 | 4117 | 2818 | 59 | 5342 | 4042 | 62 | 6942 | 5631 | 65 | 8713 | 7410 |
95 | 4 . 5 | 59 | 5155 | 3294 | 64 | 6557 | 4697 | 66 | 8230 | 6352 | 69 | 10085 | 8208 |
120 | 4 . 5 | 64 | 6317 | 3892 | 67 | 7896 | 5471 | 71 | 9715 | 7268 | 74 | 11720 | 9273 |
150 | 4 . 5 | 68 | 7303 | 4366 | 73 | 8974 | 6033 | 76 | 11692 | 8728 | 78 | 12915 | 9951 |
185 | 4 . 5 | 72 | 8405 | 4880 | 76 | 10179 | 6654 | 80 | 13234 | 9677 | 82 | 14487 | 10931 |
240 | 4 . 5 | 77 | 10323 | 5728 | 82 | 12272 | 7676 | 85 | 15496 | 10859 | 87 | 16828 | 12231 |
300 | 4 . 5 | 82 | 12658 | 6691 | 88 | 15673 | 9406 | 90 | 18234 | 12213 | 92 | 19689 | 13668 |
400 | 4 . 5 | 89 | 15195 | 7767 | 96 | 18830 | 11402 | 100 | 21035 | 13607 | 103 | 20440 | 15160 |
500 | 4 . 5 | 96 | 18305 | 9020 | 104 | 22267 | 12982 | 107 | 24589 | 15304 | 110 | 25961 | 16874 |