AAC AAAC ACSR ACARACSACSS / Tw Galvanized Steel Wire Overhead Transmission Line Bare Aluminium Conductor Cable

Concentric lay stranded Aluminium Alloy Conductors (AAAC) are made out of high strength Aluminium-Magnesium-Silicon Alloy. Our company manufactures and supply AAAC with different variants of electrical grade alloy type 6101 and 6201. one or more strands of hard drawn 1350 aluminium alloy.

These conductors are designed to get better strength to weight ratio and offer improved electrical properties, excellent sag-tension characteristics, and superior corrosion resistance when compared with ACSR. As compared to a conventional ACSR conductor, the lighter weight, comparable strength & current carrying capacity, lower electrical losses and superior corrosion resistance have given AAAC a wide acceptance in the distribution and medium & high voltage transmission lines..

Our company can manufacture & supply AAAC on Non returnable wooden/steel reels or Returnable steel reels.

Features:

high strength to weight ratio

better sag characteristics

improved electrical properties

excellent resistance to corrosion

Application:

AAAC is used as a bare overhead conductor for power transmission and distribution lines, on aerial circuits that require a larger mechanical resistance than AAC, and a better corrosion resistance than ACSR. The sag characteristics and the strength-to-weight ratio of AAAC is better than both AAC / ACSR.

 

All Aluminum Alloy Conductors (AAAC) -IEC 61089 Standard 

Nominal cross-sectional area Actual cross-sectional area Number of strands Diameter Approximate weight of cable Nominal
breaking
load
Maximum DC
Resistance
at 20ºC
Single wire Conductor
mm2 mm2 mm mm kg/km kN Ω/km
16 18.4 7 1.83 5.49 50.4 5.43 1.7896
25 28.8 7 2.29 6.86 78.7 8.49 1.1453
40 46.0 7 2.89 8.68 125.9 13.58 0.7158
63 72.5 7 3.63 10.9 198.3 21.39 0.4545
100 115 19 2.78 13.9 316.3 33.95 0.2877
125 144 19 3.10 15.5 395.4 42.44 0.2302
160 184 19 3.51 17.6 506.1 54.32 0.1798
200 230 19 3.93 19.6 632.7 67.91 0.1439
250 288 19 4.39 22.0 790.8 84.88 0.1151
315 363 37 3.53 24.7 998.9 106.95 0.0916
400 460 37 3.98 27.9 1268.4 135.81 0.0721
450 518 37 4.22 29.6 1426.9 152.79 0.0641
500 575 37 4.45 31.2 1585.5 169.76 0.0577
560 645 61 3.67 33.0 1778.4 190.14 0.0516
630 725 61 3.89 35.0 2000.7 213.90 0.0458
710 817 61 4.13 37.2 1154.8 241.07 0.0407
800 921 61 4.38 39.5 2540.6 271.62 0.0361
900 1036 91 3.81 41.8 2861.1 305.58 0.0321
1000 1151 91 4.01 44.1 3179.0 339.53 0.0289
1120 1289 91 4.25 46.7 3560.5 380.27 0.0258
1250 1439 91 4.49 49.4 3973.7 424.41 0.0231